Discussion of Gd-EOB-DTPA dynamic enhanced MRI scan in normal liver of mice
1. Affiliated Hospital of Military Medical Science Academy of the PLA, Beijing 100071, China;
2. Institute of Disease Control and Prevention, Military Medical Science Academy of the PLA, Beijing 100071, China
Abstract:Objective: To investigate the optimal imaging parameters of MRI T1 plain scan and Gd-EOB-DTPA dynamic enhanced scan in kunming mice based on small animal experiments on conventional MRI, to provide references for the experimental study of small animal liver imaging. Methods: Ten male kunming mice(6~8 W) were performed with T1WI and T1 dynamic enhanced scanning(10-phase dynamic enhanced continuous scanning) using Siemens 3.0T MRI and special coil of wrist joint and tail vein injection. Gd-EOB-DTPA was diluted 100 times with saline. Dosage: 0.05 mL/10g, 0.1 mL/10g, 0.15 mL/10g. The time and signal intensity percentage curve was formed after T1WI plain scan and dynamic enhancement, and the shape of the curve was observed. The T1WI signal intensity of the liver, the signal intensity of the liver at the time of the development of the gallbladder and the tissue contrast of the liver and muscle signal were measured and analyzed. The enhancement rates of the liver parenchyma signal were calculated and compared with the muscle signal enhancement rates. Results: The dose of tail vein injection contrast agent was 0.1 mL/10g, and the time and signal intensity percentage curve was rising platform type, and followed by the platform type after the fourth stage, and the gallbladder developed at fifth or sixth stage. There were significant differences of the signal intensity between plain scans and enhanced scans in small animal livers, and of the signal enhancement rate between the liver parenchyma and the muscle. The contrast of the plain scan signal intensity of the liver to the muscle was significantly different from the contrast of the enhanced signal intensity of the liver. Conclusion: Small animal experiments on conventional MRI were feasible. The Gd-EOB-DTPA dynamic enhanced scan in kunming mice was also feasible. The curve of the Gd-EOB-DTPA dynamic enhanced scan showed rising platform type. The developing of gallbladder was clear. The Gd-EOB-DTPA can be used for the research of the related liver diseases.
张洪涛1,盛复庚1,邢旭东1,章 雷2,胡艳梅1,李功杰1. 小鼠正常肝脏MRI普美显动态增强扫描探讨[J]. 中国临床医学影像杂志, 2015, 26(12): 882-885.
ZHANG Hong-tao1, SHENG Fu-geng1, XING Xu-dong1, ZHANG Lei2, HU Yan-mei1, LI Gong-jie1. Discussion of Gd-EOB-DTPA dynamic enhanced MRI scan in normal liver of mice. JOURNAL OF CHINA MEDICAL IMAGING, 2015, 26(12): 882-885.
[1]钱骏,冯敢生,Truebenbach Jochen,等. 同种移植大鼠肝细胞癌模型的建立及其磁共振表现[J]. 中华放射学杂志,2002,36(5):455-458.
[2]Tamada T, Ito K, Sone T, et al. Dynamic contrast-enhanced magnetic resonance imaging of abdominal solid organ and major vessel: comparison of enhancement effect between Gd-EOB-DTPA and Gd-DTPA[J]. J Magn Reson Imaging, 2009, 29(3): 636-640.
[3]Tschirch FT, Struwe A, Petrowsky H, et al. Contrast-enhanced MR cholangiography with Gd-EOB-DTPA in patients with liver cirrhosis: visualization of the biliary ducts in comparison with patients with normal liver parenchyma[J]. Eur Radiol, 2008, 18(8): 1577-1586.
[4]Ryeom HK, Kim SH, Kim JY, et al. Quantitive evaluation of liver function with MRI using Gd-EOB-DTPA[J]. Kor J Radiol, 2004, 5(4): 231-239.
[5]Ni Y, Marcal G. Enhanced magnetic resonance imaging for tissue characterisation of liver abnormalities with hepatobiliary contrast agents: an overview of preclinical animal experiments[J]. Top Magn Reson Imaging, 1998, 9(3): 183-195.
[6]Lee SM, Lee SH, Kang HY, et al. Assessment of musculoskeletal infection in rats to determine usefulness of SPIO-enhanced MRI[J]. AJR, 2007, 189(3): 542-548.
[7]Berkowitz BA, Roberts R, Luan H, et al. Dynamic contrast-enhanced MRI measurements of passive permeability through blood retinal barrier in diabetic rats[J]. IOVS, 2004, 45(7): 2391-2398.