Abstract:Objective: To investigate the effect of organ dose modulation(ODM) on reducing radiation dose of sensitive organs in chest CT. Methods: Using a prospective case-control study design, 80 cases of patients with chest CT scan in our hospital from January to August 2019 were selected. Patients were divided into group A(n=40) and group B(n=40) by random number table method. Group A was the experimental group and group B was the control group. Patients in group A were scanned by ODM technology. Patients in group B had routine CT scan, and other parameters were as same as those in group A. Four directions tube currents, volumetric CT dose index(CTDIvol), dose length product(DLP), and effective dose(ED) were recorded at breast tissue level(anterior, left, posterior, and right) in the two groups. The region of interest(ROI) was selected from the gland region and thoracic aorta region at the breast tissue center level, and objective noise(SD) and signal-to-noise ratio(SNR) were compared. Two senior radiologists were employed to evaluate the quality of breast regional plane images on a 5-point subjective scale under the pulmonary and mediastinal Windows. Results: Among the 4 directions of breast CT tissue level in the two groups, the anterior tube current in group A was significantly lower than that in group B(P<0.05). There was no significant difference in tube current in other directions(P>0.05). Comparison of SD and SNR levels in breast region images between the two groups was statistically significant(P<0.05). Comparison of SD and SNR levels in thoracic aorta region showed no statistical significance(P>0.05). By comparing the CTDIvol and dose DLP of the two groups of patients, the difference was statistically significant(P<0.05). ED of X-ray in group A was 7.9% lower than that in group B(P<0.05). There was no significant difference in the subjective scores of the images of the transverse pulmonary window and mediastinal window between the two groups(P>0.05). Conclusion: ODM technique can effectively reduce the radiation dose of breast tissue in chest CT scan, the image quality that meets the diagnostic requirements can be obtained.
尹 炜,钟朝辉,秦翔宇,李 妍,赵田瑞,王振常. 器官剂量调制技术在女性胸部CT平扫中的应用[J]. 中国临床医学影像杂志, 2020, 31(7): 520-524.
YIN Wei, ZHONG Zhao-hui, QIN Xiang-yu, LI Yan, ZHAO Tian-rui, WANG Zhen-chang. Application of organ modulation technique in female chest CT scan. JOURNAL OF CHINA MEDICAL IMAGING, 2020, 31(7): 520-524.
[1]National Lung Screening Trial Research Team. Reduced lung-cancer mortality with low-dose computed tomographic screening[J]. N Engl J Med, 2011, 365(5): 395-409.
[2]柳杰,刘佩芳,王红彬,等. 不同附加滤过与数字乳腺X射线摄影辐射剂量和影像质量相关性的研究[J]. 中华放射学杂志,2012,46(12):1079-1082.
[3]Dixon MT, Loader RJ, Stevens GC, et al. An evaluation of organ dose modulation on a GE optima CT 660 computed tomography scanner[J]. J Appl Clin Med Phys, 2016, 17(3): 380-391.
[4]Tootell A, Szczepura K, Hogg P. Analysis of effective and organ dose estimation in CT when using mA modulation: A single scanner pilot study[J]. Radiography(Lond), 2017, 23(2): 159-166.
[5]朱卫平,王振,钟建国,等. 手臂上举姿势对胸部多层CT扫描自动管电流曝光技术的影响[J]. 中华放射学杂志,2012,46(10):948-949.
[6]何欣,张景东,杨正汉,等. 前置自适应统计迭代重建技术对超低剂量CT图像质量影响的模型研究[J]. 实用放射学杂志,2019,35(1):110-113;125.
[7]张永县,牛延涛,张丽丽,等. 胸部CT探测器宽度、螺距联合器官剂量调制技术对辐射剂量和影像质量影响的模体研究[J]. 中华放射学杂志,2019,53(6):464-469.
[8]赵永霞,左紫薇,吴艳民,等. 低管电压联合不同噪声指数和低浓度对比剂对肺动脉CT成像质量和辐射剂量的影响[J]. 中华放射学杂志,2017,51(6):451-455.
[9]American Association of Physicists in Medicine. The measurement, reporting. And management of radiation dose in CT: report of AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. AAPM Report No.96[R]. College Park: AAPM, 2008.
[10]李春志,王文生,张毅,等. 不同剂量迭代重建算法对iCT胸部图像质量影响的临床研究[J]. 中国临床医学影像杂志,2018,29(5):351-354.
[11]Gupta AK, Bakanauskas VJ, Cemidia GJ, et al. The Ras radiation resistance pathway[J]. Cancer Res, 2001, 61(10): 4278-4282.
[12]陈万青,郑荣寿,张思维,等. 2012年中国恶性肿瘤发病和死亡分析[J]. 中国肿瘤,2016,25(1):1-8.
[13]Miller AR, Jackson D, Hui G, et al. Lung nodules are reliably detectable on ultra-low-dose CT utilising model-based iterative reconstruction with radiation equivalent to plain radiography[J]. Clin Radiol, 2019, 74(5): 409.e17-409.e22.
[14]吴柯薇,钟朝辉,王振常,等. 器官剂量调制技术在头颅CT平扫中的应用[J]. 中国介入影像与治疗学,2019,16(8):491-494.
[15]胡敏霞,赵心明,宋俊峰,等. 64层螺旋CT腹部扫描参数优化的初步研究[J]. 中华放射学杂志,2011,45(3):264-269.
[16]刘彬,高思喆,王传卓,等. 低管电压联合全模型迭代重建技术在下肢动脉CTA中的应用[J]. 2018,29(9):660-663.