Application of lower extremity CT angiography with low tube voltage and iterative model reconstruction |
LIU Bin, GAO Si-zhe, WANG Chuan-zhuo, CHANG Zhi-hui, ZHENG Jia-he |
Department of Radiology, Shengjing Hospital of China Medical University, Shenyang 110004, China |
|
|
Abstract Objective: To investigate the application value of low tube voltage in combination with iterative model reconstruction(IMR) in lower extremity CT angiography(CTA). Methods: Forty-four patients were randomly divided into experimental group(n=22) and control group(n=22). All the patients underwent CTA with automatic tube current modulation. The patients in experimental group(group A) were scanned with 80 kVp tube voltage, 75 mL of contrast agent, flow rate at 3 mL/s and IMR. The patients in control group(group B) were scanned with 120 kVp, 100 mL of contrast agent, flow rate at 4 mL/s, and filtered back projection(FBP). CT values of vessel were measured on bilateral lower extremity arteries of the axial images, including aortic bifurcation, common femoral artery, middle superficial femoral,proximal popliteal artery and tibiofibular trunk artery. The standard deviation(SD) of CT value of vessel lumen was defined as image noise. The SNR and CNR were calculated. The subjective image quality was scored. The results of CT volume dose index(CTDIvol) and dose length product(DLP) were recorded. Results: The CT values、SNR and CNR were higher in group A than group B(P<0.01). There was no difference in subjective image quality between the two groups(P>0.05). The CTDIvol and DLP of group A were lower than that of group B(P<0.01). Compared with group B, the iodine load decreased by 25%. Conclusions: Lower extremity CTA with low tube voltage and IMR can provide good image quality for clinical diagnosis with a significant reduction in radiation dose and the iodine load.
|
Received: 31 October 2017
|
|
|
|
|
[1]耿欣,宋其韬,肖世骞,等. CT技术诊断下肢动脉硬化闭塞症的应用进展[J]. 国际放射医学核医学杂志,2015,39(6):501-504.
[2]Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study[J]. Lancet, 2012, 380(9840): 499-505.
[3]Oda S, Weissman G, Vembar M, et al. Iterative model reconstruction: improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT[J]. Eur Radiol, 2014, 83(8): 1408-1415.
[4]Chen GZ, Zhang LJ, Joseph Schoepf U, et al. Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography[J]. Eur Radiol, 2015, 25(5): 1453-1463.
[5]Qi L, Zhao Y, Zhou CS, et al. Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography[J]. Acta Radiol, 2015, 56(6): 659-665.
[6]Pan YN, Li AJ, Chen ZQ, et al. Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction [J]. Comput Assist Tomogr, 2016, 40(2): 272-276.
[7]王敏,李剑. 低管电压技术在腹主动脉及下肢动脉CT成像中的可行性研究[J]. 中国医学计算机成像杂志,2014,20(1):68-71.
[8]高思喆,张斌,赵福新,等. 基于全模型迭代重组算法(IMR)在头颈联合动脉CTA双低扫描中的应用[J]. 中国临床医学影像杂志,2017,28(1):64-67.
[9]Carrascosa P, Rodriguez-Granillo GA, Capunay C, et al. Low-dose CT coronary angiography using iterative reconstruction with a 256-slice CT scanner[J]. World J Cardiol, 2016, 5(10): 382-386.
[10]洒国,汪启东,吕双志,等. 低管电压低管电流联合全模型迭代重建在颈动脉CT血管造影的应用[J]. 中华放射医学与防护杂志,2017,37(6):471-475.
[11]Iyama Y, Nakaura T, Yokoyama K, et al. Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm[J]. Comput Assist Tomogr, 2016, 40(6): 941-947. |
|
|
|