A preliminary study of iterative model reconstruction technique combined with low-dose CT in coronary artery stent |
DU Heng-xin, HOU Yang, WANG Yi-jing, MA Yue |
Department of Radiology, Shengjing Hospital of China Medical University, Shengyang 110004, China |
|
|
Abstract Objective: To evaluate the effect of low-dose coronary CT combined with Iterative Model Reconstruction on the image quality of coronary artery stent. Methods: Forty-six patients with PCI were recruited to undergo coronary CT angiography, with a total of 71 stents. CT scan parameters: Prospective ECG-gated scan, tube voltage 100 kV, tube current using automatic tube current debugging technology. The original data of the patient CT scan were reconstructed by filtered back projection(FBP), advanced mixed iteration(iDOSE4) and IMR. Three groups of reconstructed images were subjectively and objectively evaluated. Results: All patients were successfully completed. The noise(26.9±3.6) and the signal-to-noise ratio(16.5±2.9) of the IMR group were significantly better than those in the iDOSE4 group(54.6±9.2, 8.2±1.8) and FBP group(78.9±11.4, 5.6±1.1)(P<0.01). In the stent cavity display, the signal-to-noise ratio and contrast noise ratio in the IMR group were the highest, and those in the FBP group were the lowest. There was statistical difference between the two groups(P<0.01). IMR group had the highest subjective score. There was no significant difference between the IMR group and the iDOSE4 group in terms of diagnostic feasibility(P=0.08). Conclusion: Low-dose coronary CT combined with IMR has lower noise and higher signal-to-noise ratio, which is beneficial to the display of coronary stent cavity.
|
Received: 15 January 2018
|
|
|
|
|
[1]Dangas GD, Claessen BE, Caixeta A, et al. In-stent restenosis in the drug-eluting stent era[J]. J Am Coll Cardiol, 2010, 56(23): 1897-1907.
[2]Yoshimura M, Nao T, Miura T, et al. New quantitative method to diagnose coronary in-stent restenosis by 64-multislice computed tomography[J]. J Cardiol, 2015, 65(1): 57-62.
[3]Alani A, Nakanishi R, Budoff MJ. Recent improvement in coronary computed tomography angiography diagnostic accuracy[J]. Clin Cardiol, 2014, 37(7): 428-433.
[4]江杰,谢晓洁,吴莉,等. 双源CT低管电压结合迭代重建评估冠状动脉支架成像的可行性[J]. 中国医学影像学杂志,2015,23(4):289-292.
[5]Ebersberger U, Tricarico F, Schoepf UJ, et al. CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction[J]. Eur Radiol, 2013, 23(1): 125-132.
[6]Naoum C, Blanke P, Leipsic J. Iterative reconstruction in cardiac CT[J]. J Cardiovasc Comput Tomogr, 2015, 9(4): 255-263.
[7]Halpern EJ, Gingold EL, White H, et al. Evaluation of coronary artery image quality with knowledge-based iterative model reconstruction[J]. Acad Radiol, 2014, 21(6): 805-811.
[8]Oda S, Weissman G, Vembar M, et al. Iterative model reconstruction: improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT[J]. Eur J Radiol, 2014, 83(8): 1408-1415.
[9]Hu MQ, Li M, Liu ZY, et al. Image quality evaluation of iterative model reconstruction on low tube voltage(80 kVp) coronary CT angiography in an animal study[J]. Acta Radiol, 2016, 57(2): 170-177.
[10]Li T, Zhang Y, Wang Y, et al. Chest CT with iterative reconstruction algorithms for airway stent evaluation in patients with malignant obstructive tracheobronchial diseases[J]. Medicine(Baltimore), 2016, 95(39): e4873.
[11]姜彦,吴润泽. CT迭代重建技术的临床应用及发展前景[J]. 中国医疗器械信息,2016,22(3):12-16.
[12]Karolyi M, Szilveszter B, Kolossvary M, et al. Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography[J]. Eur J Radiol, 2017, 87: 83-89.
[13]Mehta D, Thompson R, Morton T. Iterative model reconstruction: Simultaneously lowered computed tomography radiation[J]. Med Phys Intern J, 2013, 1(2): 147-155.
[14]谭晶,侯阳,郭文力,等. 全模型迭代重建技术在冠状动脉钙化模体扫描中的应用价值研究[J]. 中国临床医学影像杂志,2016,27(12):867-870.
[15]杨晶,高艳,李坤成,等. 比较两种低剂量CT迭代重建法与常规剂量滤波反投影重建法的图像质量[J]. 中国医学影像技术,2014,30(1):117-121.
[16]王艳,姚新宇,苏壮志,等. 高级的基于模型的迭代重建对冠脉支架显示的影响[J]. 中国医疗设备,2016,31(12):49-52.
[17]Wuest W, May MS, Scharf M, et al. Stent evaluation in low-dose coronary CT angiography: effect of different iterative reconstruction settings[J]. J Cardiovasc Comput Tomogr, 2013, 7(5): 319-325.
[18]赵春荣,徐磊,范占明. 冠状动脉CT血管造影对支架评价的研究进展[J]. 心肺血管病杂志,2016,35(2):150-153.
[19]王彦懿,初金刚,于扬,等. 不同迭代重建强度对冠状动脉小内径支架显示影响的体外实验[J]. 中国医学影像技术,2015,31(8):1271-1275. |
|
|
|