The value of different reconstruction method of 64-slice CT for quantitative assessment of left ventricular function
1. Department of Radiology, Donghua Hospital, Dongguan Guangdong 523110, China;
2. Department of Radiology, the Second Hospital Affiliated to Guangzhou Medical University, Guangzhou 510000, China
Abstract:Objective: To discuss the influence of different reconstruction methods of 64-slice CT quantitative assessment of left ventricular pump function. Methods: We collected 100 cases of patients with coronary artery CTA images data. All the patients respectively underwent coronary CTA examination and the reconstruction of the left ventricular function by two different methods(Segmentation and Simpson). Correlation of the two different reconstruction methods in evaluating left ventricular function(LVESV, LVEDV, LVSV, LVEF) was analyzed. Then the average reconstruction time of the two different CT reconstruction methods was compared. Results: The two different reconstruction method for the measurement of LVESV, LVEDV, LVSV, LVEF were highly correlated(r>0.900, P<0.01), and the values of them measured by two different methods were similar with no statistical differences. The reconstruction time of the Segmentation method(3 min45 s±23 s) was significantly shorter than the Simpson method(9 min58 s±47 s). Conclusion: The study shows that two kinds of different CT reconstruction methods in analysis of left ventricular function had high correlation. The Segmentation method in clinical application can greatly reduce the time, improve work efficiency, and minimize the influence of the operator’s subjective factors.
曾仲刚1,李雪霞1,梁俊生1,陈真平1,陶 娟1,李扬彬2. 64层CT不同重建方法定量评估左心室泵血功能的价值[J]. 中国临床医学影像杂志, 2016, 27(2): 98-100.
ZENG Zhong-gang1, LI Xue-xia1, LIANG Jun-sheng1, CHEN Zhen-ping1, TAO Juan1, LI Yang-bin2. The value of different reconstruction method of 64-slice CT for quantitative assessment of left ventricular function. JOURNAL OF CHINA MEDICAL IMAGING, 2016, 27(2): 98-100.
[1]Haider AW, Larson MG, Benjiamin EJ, et al. Increased left ventricular mass and hypertrophy are associated with increased risk for sudden death[J]. J Am Coll Cardiol, 1998, 32(5): 1454-1459.
[2]原珍团,余建群,杨志刚. 多层螺旋CT在左心功能评价中应用[J]. 生物医学工程杂志,2007,24(6):1432-1436.
[3]曾仲刚,李雪霞,谭琦瑄,等. 64层螺旋CT冠状动脉造影与左心室功能评估一站式检查[J]. 中国CT和MRI杂志,2015,13(2):27-29.
[4]黄小勇,晏子旭,张兆琪,等. 320层CT心电门控双期心脏功能扫描一站式检查的初步研究[J]. 中华放射学杂志,2011,45(1):22-25.
[5]Takuma S, Cabreriza SE, Sciacca R, et al. Determination of left ventricular mass by real-time three-dimensional echocardiography: in vitro validation[J]. Echocardiography, 2000, 17(7): 665-674.
[6]Rathi VK, Biedermann RW. Imaging of ventricular function ty cardiovascular magnetic resonance[J]. Curr Cardiol Rep, 2004, 6(1): 55-61.
[7]高波,郭启勇,岳勇,等. 64层螺旋CT与磁共振成像评价左心功能的比较研究[J]. 中国医学影像技术,2007,23(1):66-69.
[8]宋璟璟,李绍军,程瑞新,等. 64排螺旋CT不同重建法对左心室功能测量的影响[J]. 临床医学工程,2012,19(2):168-170.