Abstract:Objective: To investigate the MRI features of stony foreign body in rabbit vitreous body by susceptibility weighted imaging(SWI) and conventional sequences. Methods: Forty healthy rabbits were involved in this study. Experimental group were ten rabbits. Selected stones, porcelain, coal, graphite four stone material as foreign body(maximum diameter were 0.2 mm) that were randomly and respectively implanted into 40 right rabbit’s vitreous body. Take the left rabbits vitreous body implanted as reference, all cases were underwent T1WI, T2WI, PDWI, 3D-DESS and SWI sequences examination in 2 hours. Highest magnification was 3D-DESS sequence of conventional sequence, the diameter of foreign bodies on T2WI sequence was closed to the actual diameter, highest magnification was mIP figure of SWI sequence. Results: All of 40 stony foreign bodies, the diagnosis rate of T1WI, T2WI, PDWI, 3D-DES sequences was 75%, 83%, 68%, 93%. The diagnosis rate of Mag, Pha, mIP, SWI figures was 88%, 88%, 78%, 88%. Conclusion: 3D-DESS and SWI were sensitive sequences for detecting tiny stony foreign body in vitreous bodies, for the amplification effect that could be used for the detection of foreign bodies as a complementary method for convention MRI.
张晓楠,程敬亮,张会霞,王斐斐,文宝红. 兔眼玻璃体内微小石质异物的磁共振成像研究[J]. 中国临床医学影像杂志, 2017, 28(2): 81-84.
ZHANG Xiao-nan, CHENG Jing-liang, ZHANG Hui-xia, WANG Fei-fei, WEN Bao-hong. An investigation of tiny stony foreign body in rabbit vitreous body with MRI. JOURNAL OF CHINA MEDICAL IMAGING, 2017, 28(2): 81-84.
[1]Winter M, Wiechens B. Scanning electron microscopic findings on intraocular metallic foreign bodies[J]. Graefes Arch Clin Exp Ophthalmol, 1998, 236(8): 617-612.
[2]Chang YS, Jeong YC, Ko BY. A case of an asymptomatic intralenticular foreign body[J]. Korean J Ophathalmol, 2008, 22(4): 272-275.
[3]文宝红,程敬亮,高剑波,等. 兔眼玻璃体内鱼刺异物的影像学研究[J]. 中国临床医学影像杂志,2013,24(10):685-687.
[4]Di leva A, Lam T, Alcaide-Leon P, et al. Magnetic resonance susceptibility weighted in neurosurgery: current applications and future perspectives[J]. J Neurosurg, 2015, 123(6): 1463-1475.
[5]Blanch RJ, Scott RA. Military Ocular Injury: Presentation, Assessment and Management[J]. J R Army Med Corps, 2009, 155(4): 279-284.
[6]Williamson TH, Smith FW, Forrester JV. Magnetic resonance imaging of intraocular foreign bodies[J]. Br J Ophathalmol, 1989, 73(7): 555-558.
[7]Dou Q, Chen H, Yu LQ, et al. Automatic cerebral microbleeds detection from MR images via independent subspace analysis based hierarchical features[J]. Conf Proc IEEE Eng Med Biol Soc, 2015, 37(8): 7933-7936.
[8]Chaudhry US, De Bruin DE, Policeni BA. Susceptibility-weighted MR imaging: a better technique in the detection of capillary telangiectasia compared with T2* gradient-echo[J]. Am J Neuroradiol, 2014, 35(12): 2302-2305.
[9]Lin HY, Raman SV, Chung YC, et al. Rapid phase-modulated water excitation steady-state free precession for fat suppressed cine cardiovascular MR[J]. Cardiovasc Magn Reson, 2008, 10(1): 1-13.
[10]Chavhan GB, Babyn PS, Jankharia BG, et al. Steady-state MR imaging sequences: physics, classification, and clinical applications[J]. Radiographics, 2008, 28(4): 1147-1160.
[11]王丽娟,刘玉波,王光彬. 磁敏感加权成像原理概述[J]. 磁共振成像,2010,1(3):227-230.
[12]肖仁度. 实用眼科解剖学[M]. 太原:山西人民出版社,1980:58.
[13]施光普,张效房,李强,等. 磁共振成像与CT在眼内非磁性异物诊断和定位中的比较[J]. 中华眼科杂志,1997,33(2):100-102.
[14]Kaaouana T, de Rochefort L, Samaille T, et al. 2D harmonic filtering of MR phase images in multicenter clinical setting: toward a magnetic signature of cerebral microbleeds[J]. Neuroimage, 2015, 104(1): 287-300.
[15]Philip SS, John D, John SS. Asymptomatic Intracorneal Graphite Deposits following Graphite Pencile Injury[J]. Case Rep Ophthalmol Med, 2012, 10(4): 17-19.