Occupational dose in interventional radiology procedures
MA Heng-fei1, LI Ling-jun1, CHEN Chuang-ju1, WANG Li-zhou2, ZHOU Shi2
1.Department of Interventional Radiology, The First People’s Hospital of Pingdingshan, Pingdingshan Henan 467000, China;
2.Department of Interventional Radiology, Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
Abstract:Objective: Interventional radiology tends to involve long procedures(i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology staff. Methods: We compared the annual occupational dose(effective dose and dose equivalent) among interventional radiology staff in a hospital where 2 202 catheterization procedures were performed annually. The annual occupational doses of 6 physicians, 3 nurses, and 3 radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. Results: The annual mean±SD of effective dose(range) to the physicians, nurses, and radiologic technologists using two badges was 3.00±1.50(0.84~6.17), 1.34±0.55(0.70~2.20), and 0.60±0.48(0.02~1.43)mSv/y, respectively. Similarly, the annual mean±SD of dose equivalent range was 19.84±12.45(7.0~48.5), 4.73±0.72(3.9~6.2), and 1.30±1.00(0.2~2.7)mSv/y, respectively. The mean±SD of effective dose for the physicians was 1.02±0.74 and 3.00±1.50mSv/y for the one- and two-badge methods, respectively(P<0.001). Similarly, the mean±SD of effective dose for the nurses(P=0.186) and radiologic technologists(P=0.726) tended to be lower using the one-badge method. Conclusion: The annual occupational dose for interventional radiology staff was in the order physicians>nurses>radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.
马恒飞1,李灵军1,陈创举1,王黎洲2,周 石2. 介入放射学从业人员职业辐射剂量测量的探讨[J]. 中国临床医学影像杂志, 2017, 28(9): 665-668.
MA Heng-fei1, LI Ling-jun1, CHEN Chuang-ju1, WANG Li-zhou2, ZHOU Shi2. Occupational dose in interventional radiology procedures. JOURNAL OF CHINA MEDICAL IMAGING, 2017, 28(9): 665-668.
[1]Valentin J. Avoidance of radiation injuries from medical interventional procedures: publication 85. International Commission on Radiological Protection(IRCP) Website. store.elsevier.com/ICRP-Publication-85-Avoidance-of-Radiation-Injuries-from-Medical-Interventional-Procedures/isbn-9780080439754.Published August 2001. Accessed August 27, 2012
[2]Koenig TR, Wolff D, Mettler FA, et al. Skin injuries from fluoroscopically guided procedures. Part 1. Characteristics of radiation injury[J]. AJR, 2001, 177(1): 3-11.
[3]Koenig TR, Mettler FA, Wagner LK. Skin injuries from fluoroscopically guided procedures. Part 2. Review of 73 cases and recommendations for minimizing dose delivered to patient[J]. AJR, 2001, 177(1): 13-20.
[4]Chida K, Saito H, Zuguchi M, et al. Does digital acquisition reduce patients’ skin dose in cardiac interventional procedures? An experimental study[J]. AJR, 2004, 183(4): 1111-1114.
[5]Chida K, Saito H, Otani H, et al. Relationship between fluoroscopic time, dose–area product, body weight, and maximum radiation skin dose in cardiac interventional procedures[J]. AJR, 2006, 186(3): 774-778.
[6]Chida K, Kagaya Y, Saito H, et al. Total entrance skin dose: an effective indicator of maximum radiation dose to the skin during percutaneous coronary intervention[J]. AJR, 2007, 189(4): 989.
[7]Balter S, Hopewell JW, Miller DL, et al. Fluoroscopically guided interventional procedures: a review of radiation effects on patients’skin and hair[J]. Radiology, 2010, 254(2): 326-341.
[8]Chida K, Kato M, Saito H, et al. Radiation dose of interventional radiology system using a flat-panel detector[J]. AJR, 2009, 193(6): 1680-1685.
[9]Chida K, Ohno T, Kakizaki S, et al. Radiation dose to the pediatric cardiac catheterization and intervention patient[J]. AJR, 2010, 195(5): 1175-1179.
[10]Chida K, Takahashi T, Ito D, et al. Clarifying and visualizing sources of staff-received scattered radiation in interventional procedures[J]. AJR, 2011, 197(5): 1175.
[11]Vano E, Gonzalez L, Fernandez JM, et al. Eye lens exposure to radiation in interventional suites: caution is warranted[J]. Radiology, 2008, 248(3): 945-953.
[12]Haskal ZJ, Worgul BV. Interventional radiology carries occupational risk for cataracts[J]. RSNA News, 2004, 14(1): 5-6.
[13]Ainsbury EA, Bouffler SD, Dorr W, et al. Radiation cataractogenesis: a review of recent studies[J]. Radiat Res, 2009, 172(1): 1-9.
[14]The Radiation Council, Ministry of Education,Culture, Sports, Science and Technology, Japan.www.mext.go.jp/b_menu/shingi/housha/sonota/990401d.htm. August 21, 2001
[15]Chida K, Morishima Y, Masuyama H, et al. Effect of radiation monitoring method and formula differences on estimated physician dose during percutaneous coronary intervention[J]. Acta Radiol, 2009, 50(2): 170-173.
[16]Valentin J. The 2007 recommendations of the International Commission on Radiological Protection: publication 103. International Commission on Radiological Protection(IRCP) Website.www.icrp.org/docs/ICRP_Publication_103-Annals_of_the_ICRP_37%282-4%29-Free_extract.pdf. Published March 2007. Accessed August 27, 2012
[17]Efstathopoulos EP, Pantos I, Andreou M, et al. Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures[J]. Br J Radiol, 2011, 84(997): 70-77.
[18]Balter S, Zanzonico P, Reiss GR, et al. Radiation is not the only risk[J]. AJR, 2011, 196(4): 762-767.
[19]Balter S. Radiation need not be feared, but it must be respected[J]. AJR, 2011, 196(4): 754-755.
[20]Dauer LT, Thornton RH, Hay JL, et al. Fears, feelings, and facts: interactively communicating benefits and risks of medical radiation with patients[J]. AJR, 2011, 196(4): 756-761.
[21]Limacher MC, Douglas PS, Germano G, et al. ACC expert consensus document: radiation safety in the practice of cardiology—American College of Cardiology[J]. J Am Coll Cardiol, 1998, 31(4): 892-913.
[22]Jarvinen H, Buls N, Clerinx P, et al. Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff[J]. Radiat Prot Dosimetry, 2008, 129(1-3): 333-339.
[23]Kuipers G, Velders XL. Effective dose to staff from interventional procedures: estimations from single and double dosimetry[J]. Radiat Prot Dosimetry, 2009, 136(2): 95-100.