2007, Vol. 18 Issue (3): 199-201    DOI:
论著 Current Issue | Archive | Adv Search |
Study on image characteristics and regularity of isolated single atrium in color Doppler echocardiography
HOU Chuan-ju1, DENG Dong-an1, ZHU Xian-yang1, HAN Xiu-min1, YANG Jun2, LI Chun-hua2
1. Department of Congenital Heart Disease Internal, Shenyang Military General Hospital, Shenyang 110016, China;2. Shenzhou Hospital, Shenyang Medical College, Shenyang 110020, China
Download: PDF (918 KB)   HTML (0 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Objective: To investigate the imaging character and regularity of isolated single atrium(ISA) in color Doppler echocardiography(CDE). Methods: Thirty patients of ISA were examined with CDE. Fourteen cases of them underwent angiocardiography for correlation. All of the cases were confirmed by operation. Results: Twenty-seven cases were accurately diagnosed by CDE image with the diagnostic accuracy rate of 90.0%. The other 3 cases were misdiagnosed as partial atrioventricular septal defect. The features of CDE image in ISA had obvious characteristics: ①The parasternal long-axis view of left ventricle by 2DE showed an enlarged right ventricle and elongation and narrowing of the left ventricle outflow tract. The apical four-chamber view showed echo dropout in the interatrial septum, closure of the mitral and tricuspid valve during systole and the substitution of normal “cross” image by a “upside-down T” sign. Parasternal short axis view at the mitral valve level in 2DE showed a “broken bridge”-like anterior mitral leaflet. ②M-mode ECG showed equidirectional movement of the interventricular septum and the posterior left ventricular wall, narrowing of the outflow tract of left ventricule and a double-curve echo of the anterior leaflet of mitral valve. ③Continuous-wave Doppler assessments of pulmonary artery pressure were more than 30mmHg in all the cases. ④Color Doppler flow imaging showed colorful regurgitation flow through the mitral valve and the tricuspid valve during systole and through the pulmonary valve during diastole. Conclusions: The feature of CDE image in ISA is obvious and is valuable in diagnosis for ISA, but it should be differentiated from partial atrioventricular septal defect.
Key wordsheart defects      congenital      echocardiography      Doppler      color     
Received: 07 September 2006     
:  R541  
  R540.45  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
HOU Chuan-ju
DENG Dong-an
ZHU Xian-yang
HAN Xiu-min
YANG Jun
LI Chun-hua
Cite this article:   
HOU Chuan-ju,DENG Dong-an,ZHU Xian-yang, et al. Study on image characteristics and regularity of isolated single atrium in color Doppler echocardiography[J]. , 2007, 18(3): 199-201.
URL:  
http://www.jccmi.com.cn/EN/      OR     http://www.jccmi.com.cn/EN/Y2007/V18/I3/199
Copyright © Editorial Board of JOURNAL OF CHINA MEDICAL IMAGING
Supported by:Beijing Magtech