|
|
The feasibility study on optimization of image quality of iliac vein MSCTV by gemstone spectral CT imaging technique |
Department of Radiology, Taizhou Hospital Affiliated to Wenzhou Medical University, Linhai Zhejiang 317000, China |
|
|
Abstract Objective: To investigate the application value of gemstone spectral CT single energy imaging technique to improve the image quality of indirect iliac vein MSCTV. Methods: Forty-four patients underwent iliac vein CT enhanced scanning by the GSI technique. 50 keV, 70 keV monochromatic images and the mixed energy images, and reconstructed images of iliac vein MPR, CPR, MIP were obtained. CT value, image noise and CNR of iliac vein were measured, and subjective scores of the original data and the image quality were evaluated by two senior radiologists at double-blinded. One-way ANOVA was used for statistical analysis. Kappa test was used for the consistency of subjective scores. Results: The CT value, image noise, CNR and subjective score of iliac vein of 50 keV monochromatic images were statistically higher than those of 70 keV images and the mixed energy images. The CT values of iliac vein were (220.72±27.90) HU, (112.76±13.42) HU and (115.55±12.80) HU, respectively. The values of image noise were (29.83±5.15), (15.25±2.73) and (18.46±3.05), respectively. The values of CNR were (4.55±1.74), (3.63±1.60) and (2.68±1.22), respectively. The differences of CT value, image noise and CNR were statistically significant among three groups(F=445.404, 178.996 and 16.356, P<0.01). The consistency of subjective scores for three groups among radiologists was good(Kappa=0.806, P<0.001). Conclusion: The gemstone spectral CT single energy imaging technique can significantly improve the image quality of indirect iliac vein MSCTV.
|
Received: 09 June 2015
|
|
|
|
|
[1]胡毅,于寰,张铁. 间接法下肢深静脉CT成像中对比剂用量的探讨[J]. 中国CT和MRI杂志,2014,12(1):112-113.
[2]夏巍,吴晶涛,尹肖睿,等. 低管电压法与低管电流法在降低多层螺旋CT下肢静脉成像辐射剂量中的对比研究[J]. 中华放射学杂志,2013,47(4):368-370.
[3]李天然,钱根年,郑春雨,等. 16层螺旋CT静脉血管造影的影像分析[J]. 临床放射学杂志,2005,24(5):460-461.
[4]崔志鹏,马爱红,李天文,等. 64排螺旋CT静脉造影诊断下肢静脉血栓性病变[J]. 中国医学影像学杂志,2006,14(3):175-179.
[5]潘玉峰,张浩,郭晓华,等. 肺栓塞和下肢深静脉血栓的多层CT联合成像[J]. 放射学实践,2010,25(3):309-311.
[6]张晓鹏. 探索的精神和乐趣——CT能谱成像临床应用研究中的思考[J]. 中华放射学杂志,2011,45(8):709-712.
[7]孙骏,罗先富,王守安,等. 能谱CT单能量图像对提高肝静脉成像质量的临床应用研究[J]. 中华放射学杂志,2013,47(2):132-135.
[8]Huda W, Sealzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT[J]. Radiology, 2000, 217(2): 430-435.
[9]陈盈,米玉成,曾春光,等. HDCT能谱技术提高肝脏门静脉血管成像质量的可行性研究[J]. 临床放射学杂志,2012,31(1):61-64.
|
|
|
|