Evaluation of a standardized procedure for 13N-ammonia dynamic myocardial perfusion imaging |
Department of Nuclear Medicine, Guangdong General Hospital, Guangdong Academy of Medical Science,
Guangzhou 510080, China |
|
|
Abstract Objective: To establish and analyze its feasibility of a standardized procedure for 13N-ammonia dynamic myocardial perfusion imaging for PET/CT centers. Methods: 13N-ammonia dynamic myocardial perfusion imaging was performed on 53 patients based on the operational procedure from October 2013 to March 2015. Results: From October 2013 to September 2014, termed as primary stage, 43 samples were collected with their original dosage of(31.20±6.53)mCi and calibrated dosage of (23.37±5.22) mCi. The interval was set (4'05"±1'50") and the initial collecting counts(106) were 45.84±10.77. From October 2014 to March 2015, termed as optimizing stage, 10 samples were collected with their original dosage of (26.68±7.37) mCi and calibrated dosage of (20.39±5.41) mCi. The interval was set (3'47"±0'56") and the initial collection counts(106) were 35.08±11.55. Consequently, the images of the 53 samples were clear, indicating the excellent feasibility of this operational procedure. Conclusions: We build up a standardized procedure for 13N-ammonia dynamic myocardial perfusion imaging for PET/CT centers with good feasibility and repeatability and its promotion is recommended.
|
Received: 15 June 2015
|
|
|
|
|
[1]刘秀杰,朱承谟,丁虹,等. 中国核心脏病学三十年回顾[J]. 中华核医学杂志,2010,10(5):352-354.
[2]刘欣波,武凤艳. PET/CT心肌血流灌注显像[J]. 世界最新医学信息文摘,2013,13(19):231-233.
[3]汪娇,李剑明. PET/CT正电子心肌灌注显像剂的研究进展[J]. 中国医学影像学杂志,2014,11(21):877-880.
[4]王跃涛,胡春艾,丁雪梅,等. PET/CT在心血管疾病的应用现状和进展[J]. 现代医学,2008,36(1):65-68.
[5]Dorbala S, Di Carli MF, Delbeke D, et al. SNMMI/ASNC/SCCT guideline for cardiac SPECT/CT and PET/CT 1.0[J]. J Nucl Med, 2013, 54(8): 1485-1507.
[6]Dilsizian V, Bacharach SL, Beanlands RS, et al. Imaging guidelines for nuclear cardiology procedures: PET myocardial perfusion and metabolism clinical imaging[J]. J Nucl Cardiol, 2009, 16(4): 651.
[7]Strauss HW, Miller DD, Wittry MD, et al. Procedure guideline for myocardial perfusion imaging 3.3[J]. J Nucl Med Technol, 2008, 36(3): 155-161.
[8]王治国,赵艳娟,左峰,等. GE合成器生产几种非FDG正电子显像剂及临床应用[J]. 中国疗养医学,2013,22(10):874-876.
[9]唐刚华,王明芳,唐小兰,等. 正电子血流显像剂13N-NH3·H2O的质量控制[J]. 第一军医大学学报,2001,21(7):506-509.
[10]易畅,张祥松,史新冲,等. 探讨13N-氨水动态心肌灌注显像定量分析方法[J]. 中国医学影像技术,2012,28(2):273-276.
[11]黄钢,石洪成. 心脏核医学[M]. 上海:上海科学技术出版社,2011:58-59.
[12]莫静恩. 腺苷负荷13N-NH3 PET/CT心肌灌注显像检查的护理配合[J]. 护理研究,2008,10(265):2687.
[13]陈盛祖. 临床技术操作规范-核医学分册[M]. 北京:人民军医出版社,2009:51.
[14]Bybee KA, Lee J, Markiewicz R, et al. Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imaging[J]. J Nucl Cardiol, 2010, 17(2): 188-196. |
|
|
|