Study on using spectral CT technology for improving imaging quality of portal venography in cirrhosis |
HUANG Rui-sui, DING Ke, YIN Hua, WEI Xue, ZHAO Qin-ping, HE Fei |
(Department of Radiology, Nanning Second People’s Hospital, Nanning 530031, China) |
|
|
Abstract Objective: To investigate the effect of spectral CT technology for improving imaging quality of portal venography in cirrhosis patients. Methods: 42 patients with cirrhosis underwent enhanced CT scans spectral CT mode in the portal phase and conventional helical mode in other phase. The best contrast-to-noise ratio(CNR) for main portal veins, as well as the conventional polychromatic images were obtained in the portal phase, and volume rendering and maximum intensity projection were created to show the portal veins. CT value of the main portal vein, liver parenchyma and image noise were measured. Overall imaging quality were assessed by two radiologists with more than 10 years’ experience of abdominal imaging diagnosis. Comparison between the two groups by using independent-samples t test. Inter-observer agreement in subjective image quality was assessed by Kappa statistics. Results: The monochromatic images at 50~53 keV were found to have the best CNR for portal veins. CT value of the main portal vein and liver parenchyma, the image noise and the CNR of optimal monchromatic images were statistically significantly higher than that of polychromatic images, respectively(P<0.01). In the comparison of image quality, the optimal monochromatic reconstructed images(Kappa value=0.759) were higher than polychromatic reconstructed images(Kappa value=0.521). The image quality scores of two groups were 4.17±0.72 and 3.06±0.55. There were significant differences between the image quality scores of two groups(P<0.01). Conclusion: Monochromatic images of spectral CT could improve CNR for display portal veins and improve the image quality.
|
Received: 09 August 2016
|
|
|
|
|
[1]杨克柽,陈伟. 肝脏门静脉期CT增强的影响因素与对策[J]. 国际医学放射学杂志,2015,38(6):562-566.
[2]Kagan A, Sheikh-Hamad D. Contrast-induced kidney injury: focus on modifiable risk factors and prophylactic strategies[J]. Clin Cardiol, 2010, 33(2): 62-66.
[3]张龙敏,刘爱莲,刘义军,等. 低浓度对比剂能谱CT单能量成像对提高门静脉图像质量的研究[J]. 放射学实践,2015,30(4):360-363.
[4]王贵生,高建华,赵帅,等. 肝脏增强扫描门静脉期能谱CT与传统多层螺旋CT辐射剂量和图像质量的比较[J]. 中华放射学杂志,2013,47(4):340-348.
[5]Zhu K, Meng X, Pang P, et al. Gastric varices in patients with portal hypertension: evaluation with multidetector row CT[J]. J Clin Gastroenterol, 2010, 44(5): 108-115.
[6]谢继承,陈盈,周亚敏,等. HDCT能谱技术提高肝硬化门静脉血管成像图像质量的价值研究[J]. 医学影像学杂志,2013,23(4):532-535.
[7]张晓鹏. 探索的精神与乐趣——能谱CT临床应用研究中的思考[J]. 中华放射学杂志,2011,45(8):709-712.
[8]Zhao LQ, He W, Li JY, et al. Improving image quality in portal venography with spectral CT imaging[J]. Eur J Radiol, 2012, 81(8): 1677-1681.
[9]林晓珠,沈云,陈克敏. CT能谱成像的基本原理与临床应用研究进展[J]. 中华放射学杂志,2011,45(8):798-800.
[10]佟梓滨,刘爱莲,刘义军,等. 低浓度对比剂单能量成像对提高肝静脉成像质量的研究[J]. 中国临床医学影像杂志,2015,26(2):95-984.
[11]贺太平,于勇,段海峰,等. CT能谱成像对肝脏局灶性病变鉴别诊断价值的初步研究[J]. 实用放射学杂志,2014,30(9):1506-1509.
[12]孙俊,罗先富,王守安,等. 能谱CT单能量图像对提高肝静脉成像质量的临床应用研究[J]. 中华放射学杂志,2013,47(2):132-135. |
|
|
|