Comparative study of four types of 3D sequences at displaying the structure of both hip joints and measuring each acetabular index in children |
WU Qian-qian, LIU Hong-sheng, CHEN Yuan-kai, KUANG Min-wei, LIU Zhen-qing |
Medical Imaging Department, Guangzhou Women and Children’s Medical Center, Guangzhou 510120, China |
|
|
Abstract Objective: To analyze and compare the reliability of 3D-DESS, 3D-CISS, 3D-MEDIC, and 3D-True FISP in displaying both hip joints and measurement of each acetabular index in children. Methods: With 3.0T MRI imaging system, four types of 3D sequence were performed in all 34 cases of 6~12 years old children. The SNR of femoral head and articular cartilage, CNR, subjective image quality score and each acetabular index was analyzed. Results: The SNR of articular cartilage was as followed: 3D-MEDIC>3D-DESS/3D-CISS>3D-True FISP. The SNR of femoral head was as followed: 3D-DESS/3D-CISS>3D-MEDIC>3D-True FISP. The CNR was as followed: 3D-MEDIC/3D-True FISP>3D-DESS/3D-CISS. The subjective image quality score was as followed: 3D-MEDIC/3D-DESS>3D-CISS>3D-True FISP. There was no statistically significant difference in the measurement of acetabular index. Conclusion: 3D-MEDIC sequence shows more advantages in cartilage displaying with high CNR, while 3D-DESS and 3D-CISS sequences show more advantages in bone displaying.
|
Received: 24 January 2018
|
|
|
|
|
[1]黄艳图,何超明. 磁共振成像信噪比的评价方法[J]. 磁共振成像,2012,3(2):149-151.
[2]刘鸿圣,叶滨宾,郭启勇,等. MRI在婴幼儿先天性髋关节脱位中的应用[J]. 中华放射学杂志,2004,38(11):1210-1214.
[3]王亮,盛茂,郭万亮,等. 婴幼儿发育性髋关节脱位MRI评价[J]. 实用放射学杂志,2014,4(4):649-652.
[4]Fisher R, Brien TS, Davis KM. Magnetic resonance imaging in congenital dysplasia of the hip[J]. J Peadiatr Orthop, 1991, 11(5): 617-622.
[5]Oktay A, Gokhan G, Gokhan O. Evaluation of Bone Cortex and Cartilage of Spondyloarthropathic Sacroiliac Joint: Efficiency of Different Fat-Saturated MRI Sequences(T1-Weighted, 3D-FLASH, and 3D-DESS)[J]. Acad Radiol, 2010, 8(17): 1292-1298.
[6]Martirosian P, Schraml C, Springer F, et al. Positive Contrast MR Imaging of Tendons, Ligaments, and Menisci by Subtraction of Signals From a Double Echo Steady State Sequence(Sub-DESS)[J]. Magn Reson Med, 2014, 71(1): 294-301.
[7]Lavdas E, Topalzikis T, Mavroidis P, et al. Comparison of PD BLADE with fat saturation(FS), PD FS and T2 3D DESS with water excitation(WE) in detecting articular knee cartilage defects[J]. Magn Reson Imaging, 2013, 31(8): 1255-1262.
[8]Knuesel PR, Pfirrmann CW, Noetzli HP, et al. MR arthrography of hip: diagnostic performance of a dedicated water-excitation 3D double-echo steady-state sequence to detect cartilage lesions[J]. AJR, 2004, 183(6): 1729-1735.
[9]Rehnitz C, Klaan B, von Stillfried F, et al. Comparison of Modern 3D and 2D MR Imaging Sequences of the Wrist at 3 Tesla[J]. Fortschr Rontgenstr, 2016, 10(55): 1042-1045.
[10]杨琼,郑卓肇. DESS、MEDIC、TrueFISP磁共振扫描序列对膝关节软骨成像的比较[J]. 中国医学影像技术,2010,26(3):535-537. |
|
|
|