Value of spectrum curve from single-source dual-energy noncontrast CT imaging for #br# identifying atypical small hepatocellular carcinnoma from hepatic perfusion disorders |
XU Ming-zhe, LIU Ai-lian, SUN Mei-yu, LIU Yi-jun, LI Ye |
Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian Liaoning 116011, China |
|
|
Abstract Objective: To assess the spectral curve from noncontrast CT imaging in differentiating atypical small hepatocellular carcinnoma(SHCC) from hepatic perfusion disorders(HPD) with single-source dual-energy CT. Methods: Thirty-two histopathologically or clinically proven SHCC and HPD patients, who underwent spectral CT enhancement scanning using spectrum imaging modality(GSI) were retrospectively enrolled with 35 lesions, including 16 SHCC and 19 HPD. The atypical SHCCs were hyperattenuating in arterial phase and nearly isodense in portal venous and equilibrium phases. On polychromatic images(QC images), CT value(CT(QC) value) of SHCC, HPD and appropriate background were measured in noncontrast and arterial phase, and then on monochromatic(40 keV and 140 keV) images, thus the slope of the energy spectrum was calculated. The data from two observers were analyzed with intra-class correlation coefficients(ICC) to assess inter-observer agreement. The differences of CT(QC) value and spectral curve slope between SHCC and liver background, HPD and appropriate background were compared by paired t-test. The differences of CT(QC) value and spectral curve slope between SHCC and HPD on noncontrast and arterial phase images were compared by independent t-test. Results: The inter-observer agreements were good(ICC>0.75). In arterial phase, there were no differences of CT(QC) value or spectral curve slope between SHCC and HPD. On unenhanced imaging, there were no differences of CT(QC) value between SHCC and background, HPD and background, or SHCC and HPD. However, there were significant differences of spectral curve slope between SHCC and background, SHCC and HPD((0.19±0.12) vs (0.00±0.12), (0.19±0.12) vs (0.04±0.17), P<0.05). There was no difference of spectral curve slope between HPD and background. Conclusion: The single-source dual-energy CT noncontrast imaging provides a new convenient, safe and reliable method on the basis of spectral curve features to identify atypical SHCC and HPD which were difficult to differentiate on three phase enhanced imaging by conventional CT.
|
Received: 03 May 2016
|
|
|
|
|
Cite this article: |
XU Ming-zhe,LIU Ai-lian,SUN Mei-yu, et al. Value of spectrum curve from single-source dual-energy noncontrast CT imaging for #br# identifying atypical small hepatocellular carcinnoma from hepatic perfusion disorders[J]. JOURNAL OF CHINA MEDICAL IMAGING, 2017, 28(1): 44-48.
|
|
|
|
URL: |
http://www.jccmi.com.cn/EN/ OR http://www.jccmi.com.cn/EN/Y2017/V28/I1/44 |
[1]吕培杰. CT能谱成像在小肝癌检测中的应用价值[J]. 放射学实践,2011,26(3):321-324.
[2]裴贻刚,胡道予. 肝脏一过性灌注异常的MSCT表现及其原因探讨[J]. 放射学实践,2010,25(7):776-779.
[3]鞠烨,刘爱连,汪禾青,等. 能谱曲线鉴别诊断良恶性浆膜腔积液[J]. 中国医学影像技术,2012,28(12):2239-2242.
[4]杨璐,王守安,朱庆强,等. CT能谱成像鉴别肝脏微小转移瘤与小囊肿[J]. 中国医学影像技术,2013,29(1):92-96.
[5]杨传红,于德新,王琳琳,等. CT能谱成像在肝细胞癌与肝转移瘤鉴别中的价值[J]. 医学影像学杂志,2014,24(11):1931-1935.
[6]Zhang D, Li X, Liu B. Objective characterization of GE discovery CT750 HD scanner: Gemstone spectral imaging mode[J]. Med Phys, 2011, 38(3): 1178-1188.
[7]刘爱连,沈云. 能谱CT临床应用图谱[M]. 北京:人民军医出版社,2012:22-23.
[8]Karcaaltlncaba M, Aktaq A. Dual-energy CT revisited with multidetector CT: Review of principles and clinical applications[J]. Diagn Interv Radiol, 2011, 17(3): 181-194.
[9]JAhn JH. Nontumorous arterioportal shunts in the liver: CT and MRI findings considering mechanisms and fate[J]. Eur Radiol, 2010, 20(2): 385-394.
[10]常燕翔,张雯,颜志平,等. 肝脏灌注异常的CT表现及意义[J]. 中国CT和MRI杂志,2015,13(12):62-64.
[11]Megibow AJ, Chandarana H, Hindman NM, et al. Increasing the Precision of CT measurements with dual-energy scanning[J]. Radiology, 2014, 272(3): 618-621.
[12]Agrawal M, Pinho D, Kulkarni N, et al. Oncologic Applications of Dual-Energy CT in the Abdomen[J]. Radiographics, 2014, 34(3): 589-612.
[13]李明英. CT能谱成像对肺内良恶性肿块诊断的初步研究[D]. 济南:山东大学,2013:16-17. |
|
|
|