活体肝移植术前64层螺旋CT肝体积评估的实验研究
周 星1,周怀琪1,郭吉刚1,曹晓锋2,陈应泰1,徐 凤1
1. 兰州大学第一医院,甘肃 兰州 730000;2. 兰州大学第二医院泌尿外科,甘肃 兰州 730000
Experimental study of preoperative volume evaluation in living donor liver transplantation using 64-slice spiral CT
ZHOU Xing1, ZHOU Huai-qi1, GUO Ji-gang1, CAO Xiao-feng2, CHEN Ying-tai1, XU Feng1
1. The First Hospital of Lanzhou University, Lanzhou 730000, China;2. Department of Urology, the Second Hospital of Lanzhou University, Lanzhou 730000, China
全文: PDF (0 KB)   HTML (0 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 目的:利用64层螺旋CT测量家兔肝脏体积,并模拟供肝切取及灌注的过程探讨CT肝体积测量的准确度,分析CT测量值与实际肝体积数值差异的原因和体积与重量的关系。方法:选取健康家兔30只,随机分为实验组、对照组,采用64层螺旋CT行兔肝三期增强扫描,在后处理工作站上分别测量门静脉期、肝静脉期1mm、3mm兔肝全肝体积;实验组模拟供肝切除及灌注过程后取出肝脏,对照组结扎血管后取出肝脏,利用排水法、称重法测量两组实际肝体积及重量,用统计软件SPSS 13.0分析数据。结果:实验组、对照组不同层厚、时相CT测量体积与实际肝体积之间差异分别为20.2%±0.5%、6.29%±0.43%,实验组、对照组肝脏密度分别为(1.000±0.011)g/ml、(1.003±0.007)g/ml。供肝切取和灌注是造成肝脏实际体积与CT测量体积差异的主要原因(F=420.380,P<0.05)。两组不同层厚不同时相CT测量体积与实际体积呈正相关(r值均>0.975,P<0.001),不同层厚、不同时相CT测量体积的差异无统计学意义(P>0.05,P>0.05),两独立样本t检验表明两组肝脏密度无明显差异(t=-1.076,P=0.294>0.05)。结论:CT测量肝体积与实际肝体积呈正相关,供肝切取和灌注是造成两者之间差异的主要原因。64层螺旋CT评估肝脏体积有较好的准确度及可重复性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
周星
周怀琪
郭吉刚
曹晓锋
陈应泰
徐凤
关键词 肝移植体层摄影术螺旋计算机动物实验    
AbstractObjective: To study the accuracy of liver volume measurement using 64-slice spiral CT(64-SCT) and analyze sources of such inaccuracies with regard to CT liver volume and actual liver volume through simulating donor liver resected with perfusion of liver transplantation, and analyze relationship of actual liver volume and the weight of the liver. Methods: Thirty rabbits were randomly assigned as experiment group and control group(15 for each); thirty rabbit livers were scanned using 64-SCT at three enhancement phases. The imaging data with two axial 2-D CT slices (1mm and 3mm) at the hepatic venous phase and portal venous phase was used for whole liver volumetry or measured on a dedicated image post-processing work station; Each actual liver volume and their weight were measured by water displacement and scales immediately, experiment group were simulated donor liver perfusion of liver transplantation, control group liver blood vessel were ligated prior to resection respectively. Results: The difference of CT liver volume and actual liver volume in the two groups were 20.2%±0.5%, 6.29%±0.43%, respectively. Liver density was (1.000±0.011)g/ml, (1.003±0.007)g/ml respectively. The CT liver volume were positively of the two groups correlated with actual liver volume(r=0.981, r=0.979, r=0.977, r=0.985, r=0.992, r=0.988, r=0.982, r=0.987, P<0.001), ANOVA indicated liver resected with perfusion of liver transplantation was the main sources of such inaccuracies with regard to CT liver volume and actual liver volume (F=420.380, P<0.05). No significant difference between the difference of CT liver volume in two slices and two phases(P>0.05, P>0.05), independent-sample t-test indicated liver density of two groups has no significant difference(t=-1.076, P>0.05). Conclusion: The positive correlation between CT liver volume and actual liver volume, the main sources of such difference between CT liver volume and actual liver volume was liver resected with perfusion of liver transplantation. 64-SCT can assess the liver volume correctly and can be repeatedly.
Key wordsLiver transplantation    Liver    Tomography    spiral computed    Animal experimentation
收稿日期: 2008-09-30     
:  R657.3  
  R814.42  
通讯作者: 周怀琪   
引用本文:   
周 星;周怀琪;郭吉刚;曹晓锋;陈应泰;徐 凤. 活体肝移植术前64层螺旋CT肝体积评估的实验研究[J]. , 2009, 20(5): 331-334.