Current status and progress of 3D-ASL for ischemic cerebrovascular disease
REN Dong-qing1, HE Dan2, BIAN Jie1
1. Department of Radiology, the Second Hospital of Dalian Medical University, Dalian Liaoning 116027, China;
2. Department of Radiology, the People’s Hospital of Liaoning Province, Shenyang 110016, China
Abstract: Recently, a noncontrast method of measuring cerebral blood flow(CBF) using 3D-arterial spin labeling(3D-ASL) has become feasible in the clinical setting. 3D-ASL has a great help in the diagnosis and treatment of ischemic cerebrovascular disease. This review summarizes the 3D-ASL technology, the influence factors of CBF and the current status and progress of 3D-ASL in ischemic cerebrovascular disease.
任冬晴1,何 丹2,边 杰1. 3D-ASL在缺血性脑血管病的研究现状与进展[J]. 中国临床医学影像杂志, 2016, 27(10): 743-746.
REN Dong-qing1, HE Dan2, BIAN Jie1. Current status and progress of 3D-ASL for ischemic cerebrovascular disease. JOURNAL OF CHINA MEDICAL IMAGING, 2016, 27(10): 743-746.
[1]Zhang SX, Yao YH, Zhang S, et al. Comparative Study of DSC-PWI and 3D-ASL in Ischemic Stroke Patients[J]. J Huazhong Univ Sci Technolog Med Sci, 2015, 35(6): 923-927.
[2]Al-Bachari S, Parkes LM, Vidyasagar R, et al. Arterial spin labelling reveals prolonged arterial arrival time in idiopathic Parkinson’s disease[J]. Neuro Image Clin, 2014, 1(6): 1-8.
[3]Ishimori Y, Monma M, Kawamura H, et al. Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression[J]. Radiol Phys Technol, 2011, 4(1): 78-83.
[4]Helle M, Norris DG, Rüfer S. Superselective pseudocontinuous arterial spin labeling[J]. Magn Reson Med, 2010, 64(3): 777-786.
[5]Wu B, Lou X, Wu X, et al. Intra- and inter scanner reliability and reproducibility of 3D whole-brain pseudo-continuous arterial spin-labeling MR perfusion at 3T[J]. J Magn Reson Imagine, 2014, 39(2): 402-409.
[6]Borogovac A, Asllani I. Arterial Spin Labeling(ASL) fMRI: advantages, theoretical constrains and experimental challenges in neurosciences[J]. Int J Biomed Imaging, 2012, 2012: 818456.
[7]Wong EC. Vessel-encoded arterial spin-labeling using pseudocontinuous tagging[J]. Magn Reson Med, 2007, 58(6): 1086-1091.
[8]Zaharchuk G. Artertial Spin Label Imaging of Acute Ischemic Stroke and Transient Ischemic attack[J]. Neuroimaging Clin N Am, 2011, 21(2): 285-301.
[9]Günther M, Oshio K, Feinberg DA, et al. Single-shot 3D imaging technique improve arterial spin labeling perfusion measurement[J]. Magn Reson Med, 2005, 54(2): 491-498.
[10]Vidorreta M, Wang Z, I Rodríguez, et al. Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences[J]. Neuroimage, 2013, 1(66): 662-671.
[11]Ghai S, Rajan DK, Asch MR, et al. Efficacy of embolization in traumatic uterine vascular malformations[J]. J Vasc Interv Radiol, 2003, 14(11): 1401-1408.
[12]胡莹莹,王晔,谢晟. 头颅位置对三维伪连续脉冲动脉自旋标记序列测量脑血流的影响[J]. 中国医学影像技术,2013,29(5):805-808.
[13]Ferré JC, Bannier E, Raoult H, et al. Arterial spin labeling(ASL) perfusion: techniques and clinical use[J]. Diag Interv Imaging, 2013, 94(12): 1211-1223.
[14]娄昕,吴冰,吴新淮,等. 正常成人听皮层磁共振动脉自旋标记灌注成像的可重复性研究[J]. 中华耳科学杂志,2013,11(1):54-58.
[15]金平,林敏,钱琦,等. 正常老年人主要脑功能区血流灌注的3D-ASL初探[J]. 浙江中医药大学学报,2015,39(4):282-285.
[16]Deibler AR, Pollock JM, Kraft RA, et al. Arterial spin-labeling in routine clinical practice, part 1: technique and artifacts[J]. Am J Neuroadiol, 2008, 29(7): 1228-1234.
[17]Qiao XJ, Salamon N, Wang DJ, et al. Perfusion Deficits Detected by Arterial Spin Labeling(ASL) in TIA Patients with negative diffusion and vascular imaging[J]. Am J Neuroradiol, 2013, 34(11): 2125-2130.
[18]Roberts DA, Detre JA, Bolinger L, et al. Renal perfusion in humans: MR imaging with spin tagging of arterial water[J]. Radiology, 1995, 196(1): 281-286.
[19]Dai W, Robson PM, Shankaranarayanan A, et al. Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging[J]. Magn Reson Med, 2012, 67(5): 1252-1265.
[20]Chen Y, Wang DJ, Detre JA. Comparison of arterial transit times estimated using arterial spin labeling[J]. MAGMA, 2012, 25(2): 135-144.
[21]Yamashita K, Yoshiura T, Hiwatashi A, et al. Differentiating primary CNS lymphoma from glioblastoma multiforme: assessment using arterial spin labeling, diffusion-weighted imaging, and 18F-fluorodeoxyglucose positron emission tomograph[J]. Neuroradiology, 2013, 55(2): 135-143.
[22]初国新,衣闯,方昊,等. 3D-ASL动脉自旋标记灌注技术及MRA联合应用在脑缺血疾病影像诊断价值[J]. 中国实验诊断学,2013,17(6):1136-1137.
[23]Chaves CJ, Silver B, Schlaug G, et al. Diffusion- and perfusion-weighted MRI patterns in borderzone infarcts[J]. Stroke, 2000, 31(5): 1090-1096.
[24]Mlynash M, Olivot JM, Tong DC, et al. Yield of combined perfusion and diffusion MR imaging in hemispheric TIA[J]. Neurology, 2009, 72(13): 1127-1133.
[25]陈旭高,邹建勋,王明杰,等. 3.0T ASL与MRA技术诊断左侧大脑低灌注伴多发血管狭窄1例[J]. 心脑血管病防治,2014,14(5):437-438.
[26]钟井松,沈海林,丁乙,等. 64层CT灌注成像对短暂性脑缺血发作患者的血流动力学评价[J]. 中国医学影像学杂志,2010,18(5):420-425.
[27]Grade M, Hernandez Tamames JA, Pizzini FB, et al. A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice[J]. Neuroradiology, 2015, 57(12): 1181-1202.
[28]任彦,姚振威,徐斌,等. 3D-pCASL和DCE-MRI定量评价烟雾病侧支循环和血管通透性的初步应用[J]. 临床放射学杂志,2016,35(1):18-23.
[29]Zaharchuk G, Do HM, Marks MP, et al. Arterial spin-labeling MRI can identify the presence and intensity of collateral perfusion in patients with moyamoya disease[J]. Stroke, 2011, 42(9): 2485-2491.
[30]Qiu M, Paul Maguire R, Arora J, et al. Arterial transit time effects in pulsed arterial spin labeling CBF mapping: insight from a PET and MR study in normal human subjects[J]. Magn Res Med, 2010, 63(2): 374-384.
[31]Qin Q, Huang AJ, Hua J, et al. 3D Whole-Brain Perfusion Quantification using Pseudo-Continuous Arterial Spin Labeling MRI at Multiple Post-Labeling Delays: Accounting for Both Arterial Transit Time and Impulse Response Function[J]. NMR Biomed, 2014, 27(2): 116-128.
[32]张水霞,张顺,姚义好,等. 3D-ASL与DSC-PWI在缺血性脑梗死患者中的对比研究[J]. 放射学实践,2014,29(8):901-905.
[33]娄昕,蔡幼铨,马林,等. 动脉自旋标记法磁共振成像在颈动脉狭窄性脑缺血疾病中的初步应用[J]. 中国医学影像学杂志,2007,15(2):88-91.
[34]van Osh MJ, Teeuwisse WM, van Walderveen MA, et al. Can arterial spin labeling detect white matter perfusion signal?[J]. Magn Reson Med, 2009, 62(1): 165-173.
[35]Zhang J, Zaharchuk G, Moseley M, et al. Pulsed continuous arterial spin labeling(pcASL) with prospective motion correction(PCASL-PROMO)[J]. Magn Reson Med, 2014, 72(4): 1049-1056.
[36]罗海龙,黄力. 动脉自旋标记的新进展及其在缺血性脑血管病的应用[J]. 国际医学放射学杂志,2014,37(1):58-62.
[37]王梅云,戴建平,程敬亮,等. 动脉血质子自旋标记与动态磁敏感对比MRI在急性脑缺血患者中的应用价值[J]. 中华放射学杂志,2007,41(11):1162-1165.