低剂量CT扫描技术在头颈部CTA中的应用价值研究
李飞飞,金 彪,邹 明,张海兵,李 君,王永杰
上海交通大学医学院附属新华医院崇明分院放射科,上海 202150
The application value of low dose CT scanning technology in CTA of head and neck
LI Fei-fei, JIN Biao, ZOU Ming, ZHANG Hai-bing, LI Jun, WANG Yong-jie
Department of Radiology, Chongming Branch of Xinhua Hospital Affiliated toShanghai Jiaotong University, Shanghai 202150, China
全文: PDF (0 KB)   HTML (0 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 目的:探讨低剂量CT(低管电压)扫描技术在头颈部CTA中的临床应用价值。方法:将55例BMI<22.9 kg/m2的成年头颈部血管受检者随机分成两组,分别采用常规剂量(120 kV、175 mA)和低剂量(80 kV、175 mA)进行64排螺旋CT扫描,利用InSpace、Neuro DSA、3D图像后处理软件对图像进行后处理,分析两组受检者的图像质量和诊断价值评估,并使用卡方检验对两组数据进行统计学比较。同时,记录两组患者所接受的辐射剂量值。结果:结果显示常规剂量图像质量略高于低剂量组,但无统计学意义(P>0.05)。信噪比方面低剂量组图像颗粒略增粗,但不影响诊断质量,无统计学意义(P>0.05)。两组患者的BMI值无统计学差异(P>0.05)。低剂量组所接受的辐射剂量远低于常规剂量组,CTDlvol与DLP值分别下降71.22%和72.03%。两组病例中分别有1例图像质量为差的病例,经调查系人为因素所致,未纳入本研究统计学范畴。结论:低剂量CTA扫描技术完全可以运用于头颈部血管性病变的斑块筛查、血管狭窄度评估及支架植入术后评估等,同时可大大降低受检者的医源性辐射剂量。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
李飞飞
金彪
邹明
张海兵
李君
王永杰
关键词 脑血管障碍体层摄影术螺旋计算机血管造影术    
AbstractObjective: To discuss the value of clinical application of low dose CT angiography(CTA) (low voltage) in head and neck. Methods: Fifty-five adults(BMI<22.9 kg/m2) underwent 64-row head and neck CTA examinations. They were randomly divided into two groups that is those using conventional dose(120 kV, 175 mA) and those using low dose(80 kV, 175 mA) scanning protocols, respectively. InSpace, Neuro DSA, 3D image software were used for postprocessing. Image quality and diagnostic value of the two groups were assessed, the chi-square test was used for statistical comparison of the two groups. The radiation dose of the two groups were also recorded. Results: The results showed that the quality of routine dose image is slightly higher than that of low dose group, but with no statistical significance(P>0.05). In the low dose group, the image particles were slightly rough, but did not affect diagnosis, there was no statistical significance(P>0.05). The BMI of the two groups showed no statistical significance(P>0.05). Radiation dose received by low dose group was lower than that of conventional dose group significantly with CTDlvol and DLP decreased 71.22% and 72.03%, respectively. In each of the two groups, there was 1 case which image quality was poor, respectively, was due to technical factors through investigation, was included as the research category. Conclusion: Low dose CTA scanning technique can be applied for head and neck vascular lesions including plaque screening, vascular stenotic degree evaluation before and after stent implantation. Meanwhile, it can greatly reduce the radiation dosage received by the patients.
Key wordsCerebrovascular disorders    Tomography    spiral computed    Angiography
收稿日期: 2013-06-19     
:  R743  
  R814.42  
  R814.43  
通讯作者: 金彪   
引用本文:   
李飞飞;金 彪;邹 明;张海兵;李 君;王永杰. 低剂量CT扫描技术在头颈部CTA中的应用价值研究[J]. , 2013, 24(11): 761-764.
LI Fei-fei;JIN Biao;ZOU Ming;ZHANG Hai-bing;LI Jun;WANG Yong-jie. The application value of low dose CT scanning technology in CTA of head and neck. , 2013, 24(11): 761-764.
链接本文:  
http://www.jccmi.com.cn/CN/      或     http://www.jccmi.com.cn/CN/Y2013/V24/I11/761
  友情链接
版权所有 © 2015 《中国临床医学影像杂志》编辑部
地址:沈阳市和平区三好街36号 邮编:110004 电话/传真: 024-23925069 电子信箱: jccmisy@sina.cn
本系统由北京玛格泰克科技发展有限公司设计开发